ZX-E
Intelligente induktive Messsensoren
Die Familie ZX-E stellt die beste Lösung für die exakte Messung von Metallobjekten dar Diese Sensoren empfehlen sich insbesondere für den Einsatz unter widrigen Umgebungsbedingungen wie beispielsweise in der Automobil- oder metallverarbeitenden Industrie.
- Hohe Auflösung: 1 µm
- Kurze Ansprechzeit: 150 µs
- Problemloser Austausch des Sensorkopfs
- Modulares Plattformkonzept für unterschiedliche Erfassungstechnologien
- Einfache Linearitätsanpassung für beliebige Metalle
Spezifikationen & Bestellinfo
Ordering information
Sensors
Sensor heads
, | ||||
Amplifier units
Note: Compatible connection with the sensor head.
Accessories (order separately)
Calculating unit
Amplifier mounting brackets
SmartMonitor sensor setup tool for Personal Computer connection
Cables with connectors on both ends (for extension)
*
undefined
* Robot cable models are also available. The model numbers are ZX-XC_R.
Specifications
Sensor heads
Magnetic metals |
||||||||
6
6.
Accuracy: The resolution is the deviation (
±3
σ) in the linear output when connected to the ZX-EDA amplifier unit. The above values indicate the deviations observed 30 minutes after the power is turned ON.
(The resolution is measured with Omron's standard reference object at ½ of the measurement range with the ZX-EDA set for the maximum average count of 4,096 per period.) The resolution is given at the repeat accuracy for a stationary workpiece, and is not an indication of the distance accuracy. The resolution may be adversely affected under strong electromagnetic fields. |
||||||||
(including amplifier unit) |
||||||||
1,000 VAC, 50/60 Hz for 1 min between charged parts and case |
||||||||
10 to 55 Hz with 1.5-mm double amplitude for 2 h each in X, Y, and Z directions |
||||||||
Amplifier units
2. Models with protective spiral tubes are also available. Add a suffix of “-S” to the above model numbers when ordering. (Example: ZX-ED01T-S)
6.
Accuracy: The resolution is the deviation (
±3
σ) in the linear output when connected to the ZX-EDA amplifier unit. The above values indicate the deviations observed 30 minutes after the power is turned ON.
(The resolution is measured with Omron's standard reference object at ½ of the measurement range with the ZX-EDA set for the maximum average count of 4,096 per period.)
The resolution is given at the repeat accuracy for a stationary workpiece, and is not an indication of the distance accuracy. The resolution may be adversely affected under strong electromagnetic fields.
7. Linearity: The linearity is given as the error in an ideal straight line displacement output when measuring the standard reference object. The linearity and measurement values vary with the object being measured.
9. Temperature characteristic: The temperature characteristic is measured with Omron's standard reference object at ½ of the measurement range.
12.
The response speed of the linear output is calculated as the measurement period x (average count setting + 1) (with fixed sensitivity).
The response speed of the judgement outputs is calculated as the measurement period x (average count setting + 1) (with fixed sensitivity).
2. Models with protective spiral tubes are also available. Add a suffix of “-S” to the above model numbers when ordering. (Example: ZX-ED01T-S)
6.
Accuracy: The resolution is the deviation (
±3
σ) in the linear output when connected to the ZX-EDA amplifier unit. The above values indicate the deviations observed 30 minutes after the power is turned ON.
(The resolution is measured with Omron's standard reference object at ½ of the measurement range with the ZX-EDA set for the maximum average count of 4,096 per period.)
The resolution is given at the repeat accuracy for a stationary workpiece, and is not an indication of the distance accuracy. The resolution may be adversely affected under strong electromagnetic fields.
7. Linearity: The linearity is given as the error in an ideal straight line displacement output when measuring the standard reference object. The linearity and measurement values vary with the object being measured.
9. Temperature characteristic: The temperature characteristic is measured with Omron's standard reference object at ½ of the measurement range.
12.
The response speed of the linear output is calculated as the measurement period x (average count setting + 1) (with fixed sensitivity).
The response speed of the judgement outputs is calculated as the measurement period x (average count setting + 1) (with fixed sensitivity).
Wie können wir Ihnen helfen?
Wenn Sie eine Frage haben oder ein Angebot anfordern möchten, kontaktieren Sie uns oder senden Sie eine Anfrage.
Ihr Kontakt ZX-E

Vielen Dank für Ihre Anfrage. Wir setzen uns umgehend mit Ihnen in Verbindung.
Es liegen zur Zeit technische Probleme vor. Ihre Übertragung war nicht erfolgreich. Entschuldigen Sie dies bitte und versuchen es später noch einmal. Details
DownloadAngebot für ZX-E
Über dieses Formular erhalten Sie ein Angebot zu Ihrem ausgewählten Produkt. Bitte füllen Sie alle Felder aus, die diese * Markierung besitzen. Ihre persönlichen Daten werden natürlich vertraulich behandelt.

Vielen Dank für Ihre Angebots-Anfrage, die wir schnellstmöglich beantworten werden.
Es liegen zur Zeit technische Probleme vor. Ihre Übertragung war nicht erfolgreich. Entschuldigen Sie dies bitte und versuchen es später noch einmal. Details
Download